IKA® calorimeter Package C 1 3/12

Availability: In Stock availability graphics

  • Manufacturer
  • Height
    0 cm
  • Length
    0 cm
  • Width
    0 cm
  • Product Description
  • Product Features
  • To Download
  • Add to the product comparison toolCompare
Added to the product comparison tool
You may add 2 to 4 products
You may add 4 products maximum
Go to Comparison Tool

Product Description

C 1 Package 3/12

The C 1 static jacket oxygen bomb calorimeter provides a high degree of automation and has the smallest calorimeter footprint available. It operates according to DIN 51900 and ISO 1928. The temperature readings are analyzed according to the classical isoperibol method of Regnault Pfaundler.

With the package 3/12 including C 1.20 water heater it is possible to operate the C 1 with drinking-quality tap water in a temperature range of 5 °C to 25 °C (water temperature < 21°C: measuring mode 22°C/ water temperature > 21 °C: measuring mode 30°C). A chiller is no longer required. The C 1.20 heater serves to maintain the correct temperature of the tap water, which must be connected to the heater at a maximum pressure of 6 bar/0.6 MPa. C 25 pressure regulating gauge is recommended as an accessory if the pressure is higher or cannot be maintained.

Scope of delivery

  • C 1 calorimeter
  • C 1.12 combustion chamber
  • C 1.20 water heater


The scope of delivery includes all parts necessary to set up the unit. Additionally it includes wear parts and consumables for the first approximately 500 experiments including 25 calibrations. The catalytic activated, halogen resistant combustion chamber C 1.12 is specifically designed for the combustion of samples that contain halogens and sulfur ( > 3 % ). It is equipped with the C 5010.5 large crucible holder and C 6 large quartz crucible.

Scope of delivery

  • C 1 S000
  • C 1.12 Combustion chamber, halogen resistant
  • C 1.20 Heater

 

Technical Data

Measuring range max.

40000 J

Measuring mode static jacket 22°C

yes

Measuring mode static jacket 30°C

yes

Measurements/h static jacket

4

Reproducibility static jacke (1g benzoic acid NBS39i)

0.15 %RSD

Working temperature

20 - 30 °C

Temperature measurement resolution

0.0001 K

Cooling medium temperature

18 - 29 °C

Cooling medium permissible operating pressure

1.5 bar

Cooling medium

tap water

Type of cooling

flow

Flow rate

50 - 60 l/h

Rec. flow rate at 18°C

55 l/h

Oxygen operating pressure max.

40 bar

Interface scale

RS232

Interface printer

RS232

Interface PC

RS232

Oxygen filling

yes

Degasification

yes

Decomposition vessel integrated

yes

Decomposition vessel, halogen resistant

yes

Analysis according to DIN 51900

yes

Analysis according to ISO 1928

yes

Dimensions (W x H x D)

290 x 280 x 300 mm

Weight

15 kg

Permissible ambient temperature

5 - 40 °C

Permissible relative humidity

80 %

Protection class according to DIN EN 60529

IP 20

RS 232 interface

yes

USB interface

yes

Voltage

100 - 240 V

Frequency

50/60 Hz

Power input

120 W

 

 

 

Product Features

  • Height
    0 cm
  • Length
    0 cm
  • Width
    0 cm